PRODUCTS
- Distribution Transformer
- Resin Casting Dry Type Power Transformer
- Whole-sealed Type Distribution Power Transformer
- Electrical Power Fitting
- Power Transmission and Distribution Fittings
- Power Line Fittings
- Power Line Helical Fittings
- High Voltage Outdoor Electrical Equipment
- Copper and Aluminum Contact Arms
- Lightening Protection Grounding Clamps
- Electric Wire & Cable and Accessories
- Rubber Sheathed Cable for General Purposes
- Rubber Insulated Cables Used in Open Countr
- Flame-retardant Rubber Sheathed Cables for Mining Purposes
- PVC Insulated Cable for House Wiring
- XLPE Insulated Power Cable
- PVC Insulated Power Cable
- Low-smoke Halogen-free Flame-retardant and Fire-resistant Cables
- Control Cables
- Overhead Conductors and Cables
- Aluminum wire and ACSR
- Special Cables
- Elevator Cable
HOTLINE
0577-57157777
Special Cables
Teflon lnsulated Power Cable
- Share:
1. Application
This product is suitable for fixed power transmission lines of rated voltage (Uo/U) 0.6/1kV and below where high working temperature is available.
This product is suitable for fixed power transmission lines of rated voltage (Uo/U) 0.6/1kV and below where high working temperature is available.
2. Code and Description
Code | Description | Working Temperature |
FF-20 | F46 insulated & sheathed power cable | -60℃ -200℃ |
FF22-200 | F46 insulated steel tape arrmored F46 sheathed power cable | -60℃ -200℃ |
FV105 | F46 insulated 105℃ PVC sheathed power cable | -15℃ -105℃ |
FV22-105 | F 46 insulated steel tape armored 105℃ PVC sheathed power cable | -15℃ -105℃ |
4. Models Available
Code | No. of Cores | Sectional Area (mm2) |
FF-200 | 1, 2, 3, 4, 3+1 | 1.5-240 |
FV-105 | 1, 2, 3, 4, 3+1 | 1.5-185 |
FF22-200 | 2, 3, 4, 3+1 | 4-185 |
FV22-105 | 2, 3, 4, 3+1 | 4-185 |
The neutral core sectional area of 3+1 core cable shall be as specified in the following table
Phase Core | Neutral Core | Phase Core | Neutral Core | Phase Core | Neutral Core |
4 | 2.5 | 25 | 16 | 95 | 50 |
6 | 4 | 35 | 16 | 120 | 70 |
10 | 6 | 50 | 25 | 150 | 70 |
16 | 10 | 70 | 35 | 185 | 95 |
5. Guide to Use
1) Rated voltage Uo/U: 0.6/1kv
2) The max. conductor temperature in normal use:
FF-200, FF22-200: 200℃
FV-105, FV22-105: 105℃
3) Ambient temperature during installation:
FF-200, FF22-200: -60 ~ 200℃
FV-105, FV22-105: -15 ~ 105℃
4) The min. bend radius is 15 times cable radius
5) The product has excellent anti-corrosion, weather-proof, flame-retardant and water-proof performances.
6) Resistance of the conductor meet requirements of GB 3956.
7) The cable shall withstand a 3.5kv/5min voltage test and no breakdown shall occur.
-
Screened Multi-pair Computer (including DCS System) Cable
-
Compensation cable
-
Heat-resistant Fire-proof Cable
-
Silicone Rubber Insulated Power Cable
-
Silicone Rubber Insulated Control Cable
-
Heat-Resistant Flat Cable
-
Teflon Insulated Heat-resistant Control Cable
-
High temperature control cable
-
Heat-Resistant & Cold-Resistant Flat Cable